UCP209-J7

Holding a bearing marked NSK UCP209 or NTN UCP209 or KOYO UCP209? Ours is UCP209-J7 — the same seat size, the same type and the same sealing and clearance design.

What this bearing is

UCP209-J7 is a Plummer block housing unit with a 45 × 85 × 49.2 mm seat, execution: open. The manufacturer's cross-reference catalogue confirms full interchangeability for 12 designations, including NSK UCP209, NTN UCP209, NTN UCP209D1.

Designation equivalents

FAG / INAUCP209-J7
NSKUCP209
NTNUCP209
NTNUCP209D1
KOYOUCP209
KOYOUCP209J
KOYOUCP209LJ
SNRUCP209
AMIUCP209
ASAHIUCP209
FAFNIRUCP209
HFBUCP209
PEERUCP209-45mm

45 × 85 × 49.2 mm

Before you replace it

This is a dimensional and design equivalent: the same seat size, the same bearing type and the same sealing and clearance design. It is not the same product — load ratings, tolerance class and grease may differ between manufacturers. For duty close to the limits or a critical application, check the datasheet of the specific design.

The same seat in another execution

These items share the mounting size and have cross-reference tables of their own. They differ in sealing, clearance or cage — exactly what decides how the bearing behaves in the seat.

Where these equivalents come from

The base number of a standard bearing is an ISO standard — 6205 is 6205 at every manufacturer. Only the suffixes describing the design differ, and those are what we translate: shields, contact seals, cage and radial clearance. Designations that mean different things at different makers are deliberately omitted.